Series 2-5000 Minihelic® II Differential Pressure Gage Series 2-5000 Minihelic® II Differential Pressure Gage FEATURES/BENEFITS • Removable lens and rear-housing provides easy, cost-effective servicing • Accuracy and value provides an excellent solution for OEM and user applications • Durable housing materials make it well-suited for rough environments and total high pressure APPLICATIONS • Room positive pressure sensing • Cabinet air-purging • Medical respiratory equipment • Air samplers • Electronic air cooling systems • Laminar flow hoods • Local indication on filter status • Face velocity on fume hood • Duct pressures อ่านเพิ่ม
SERIES AT22000,Dwyer, ATEX Approved Series 2000 Magnehelic® Differential Pressure Gage SERIES AT22000,Dwyer, ATEX Approved Series 2000 Magnehelic® Differential Pressure Gage FEATURES/BENEFITS • ATEX housing provides all the capabilities and value of the Magnehelic® in a flame & explosion proof enclosure • Quick response to pressure changes means no delay in assessing critical situations • Durable and rugged housing and high-quality components combined provides longservice life and minimized down-time • High impact strength and high temperature rated for applications where hazardous environments exist APPLICATIONS • Fan and blower pressures • Filter resistance • Air velocity • Furnace draft • Liquid levels with bubbler systems • Pressure in fluid amplifier or fluidic systems อ่านเพิ่ม
SERIES DM-1000 , DWYER DigiMag® Digital Differential Pressure and Flow Gages SERIES DM-1000 , DWYER DigiMag® Digital Differential Pressure and Flow Gages FEATURES/BENEFITS • Field programmed reduces installation time • User selectable parameters for pressure, air velocity or flow permits same device for multiple applications • Specialized filter set point for alerts when maintenance is due • Security levels permit matches the correct access to right skill • Power versatility works with 9-24 VDC or 9 V battery allows deployment in a variety of spaces wired or not APPLICATIONS • Filter monitoring • Air velocity or flow • Blower vacuum monitoring • Fan pressure indication • Duct, room or building pressures • Clean room positive pressure indication อ่านเพิ่ม
Series 160 , DWYER Stainless Steel Pitot Tube Series 160 , DWYER Stainless Steel Pitot Tube FEATURES/BENEFITS Low sensitivity to misalignment up to 15 degrees No calibration needed due to ASHRAE tip design Silver soldered connections for leak-proof operation 5/16″ models rated to 1500°F (815.5°C) APPLICATIONS Monitor or control air velocity or air flow when combined with differential pressure gage, switch or transmitter อ่านเพิ่ม
Model 166T , DWYER Telescoping Stainless Steel Pitot Tube Model 166T | DWYER Telescoping Stainless Steel Pitot Tube FEATURES/BENEFITS Adjustable length can replace up to 5 fixed length Pitot tubes Stainless steel construction resists corrosion 1.8″ diameter hemispherical tip has 1.0 flow coefficient APPLICATIONS Monitor or control air velocity or air flow when combined with differential pressure gage, switch, or transmitter where varying lengths are needed อ่านเพิ่ม
SERIES EOS , DWYER , WIRELESS OCCUPANCY SENSOR SERIES EOS | DWYER WIRELESS OCCUPANCY SENSOR With EnOcean® Technology, Ceiling or Wall Mount FEATURES/BENEFITS • Energy harvesting, no power supply or batter necessary • Ceiling mount option for a large coverage area or flat wall/corner mount in one design • Energy and cost savings by determining if lights or HVAC should be turned off based on room occupancy • Meets North American and European standards APPLICATIONS • Lighting or HVAC control • Feedback to building management system that a space is occupied อ่านเพิ่ม
MODEL OSC-200 & OSW-100 , DWYER ,OCCUPANCY SENSOR MODEL OSC-200 & OSW-100 | DWYER OCCUPANCY SENSOR Wide Viewing Angle, Easy To Install FEATURES/BENEFITS • Delay processor suppresses switch activation during momentary occupancy APPLICATIONS • Lighting control • Building energy conservation อ่านเพิ่ม
SERIES CDTV , DWYER , CARBON DIOXIDE/VOLATILE ORGANIC COMPOUND TRANSMITTER SERIES CDTV | DWYER CARBON DIOXIDE/VOLATILE ORGANIC COMPOUND TRANSMITTER Simultaneously Outputs Both CO2 / VOC FEATURES/BENEFITS • Combination VOC and CO2 outputs reduce labor and material costs • Single beam dual wavelength NDIR CO2 sensor allows for use in spaces that may be occupied 24 hours a day • VOC output is correlated to be equivalent to CO2 measurements • Ventilate using ASHRE’s occupancy-based VRP Algorithm APPLICATIONS • HVAC applications in hospitals, schools, and commercial buildings • Demand control ventilation • Odor control • Waiting rooms or other spaces that may be occupied 24 hours a day อ่านเพิ่ม
MODEL CMT200, DWYER , CARBON MONOXIDE TRANSMITTER MODEL CMT200 | DWYER CARBON MONOXIDE TRANSMITTER Current/Voltage Selectable Output, 200 PPM Range FEATURES/BENEFITS • Field selectable current or voltage outputs • Replaceable sensor • Field calibration kits APPLICATIONS • Garage ventilation • Mechanical room monitoringØ1 อ่านเพิ่ม
SERIES GSTA & GSTC , DWYER ,CARBON MONOXIDE/NITROGEN DIOXIDE GAS TRANSMITTER SERIES GSTA & GSTC | DWYER CARBON MONOXIDE/NITROGEN DIOXIDE GAS TRANSMITTER High Accuracy Electrochemical Sensor, Universal Output or BACnet & Modbus® Communication Protocol Options FEATURES/BENEFITS • Industrial grade replaceable CO or NO2 sensors • Field selectable current or voltage output on GSTA models, and field selectable BACnet or Modbus® communication on GSTC models • Integral LCD display option • Service display tool for set-up and calibration of models without a LCD APPLICATIONS • Garage or loading dock ventilation • Mechanical room monitoring อ่านเพิ่ม
SERIES CDTR , DWYER, CARBON DIOXIDE/RH/TEMPERATURE TRANSMITTER SERIES CDTR | DWYER CARBON DIOXIDE/RH/TEMPERATURE TRANSMITTER NDIR CO2 Sensor, Universal CO2/RH Outputs, Optional Relay FEATURES/BENEFITS • Digital Intelligence Temperature Compensation Algorithm (DITCA™) eliminates error due to the self heating effects of wall mount combination devices. • Single beam dual wavelength NDIR CO2 sensor • Replaceable humidity/temperature sensors • Physical hardware lockout • Service display tool available for duct mount and wall mount units without an LCD • Relay output option APPLICATIONS • Demand control ventilation in schools, office buildings, hospitals, and other indoor environments • LEED® certification อ่านเพิ่ม
SERIES CDTA , DWYER ,COMMUNICATING CARBON DIOXIDE DETECTOR SERIES CDTA | DWYER COMMUNICATING CARBON DIOXIDE DETECTOR Measures CO2, Humidity, Temperature, Temperature Set Point, and Override FEATURES/BENEFITS • Digital Intelligent Temperature Compensation Algorithm (DITCA™) corrects for errors due to self heating effects of combination wall sensors • Field selectable Modbus® and BACnet communications reduces wiring • Single beam dual wavelength CO2 sensor • Replaceable humidity/temperature sensor • Physical hardware lockout • Optional remote display tool APPLICATIONS • Demand control ventilation in schools, office buildings, hospitals, and other indoor environments • LEED® certification อ่านเพิ่ม
SERIES CDT , DWYER ,CARBON DIOXIDE/TEMPERATURE TRANSMITTER SERIES CDT | DWYER CARBON DIOXIDE/TEMPERATURE TRANSMITTER NDIR CO2 Sensor, Universal Outputs, Optional Relay FEATURES/BENEFITS • Single beam dual wavelength NDIR sensor eliminates draft due to light source aging • Integral passive temperature outputs reduce number of devices mounted in the space • Service display tool available for models without an integral LED • Optional integral display and relay output APPLICATIONS • Demand control ventilation in schools, office buildings, hospitals, and other indoor environments • LEED® certification อ่านเพิ่ม
SERIES 657 , DWYER ,RELATIVE HUMIDITY/TEMPERATURE TRANSMITTER SERIES 657 | DWYER RELATIVE HUMIDITY/TEMPERATURE TRANSMITTER Dual Channel Design for Simultaneous 4 to 20 mA Output Signals FEATURES/BENEFITS • Polymer film humidity and thin film RTD temperature sensors offer highly reliable and stable measurements. • Remote mount housing offers installation flexibility (657-1) • Rugged die-cast aluminum housing is great for industrial applications (657C-1) APPLICATIONS • Cleanroom monitoring • HVAC/building control monitoring อ่านเพิ่ม
SERIES RH-R , DWYER , HUMIDITY/TEMPERATURE TRANSMITTER SERIES RH-R | DWYER HUMIDITY/TEMPERATURE TRANSMITTER Remote Mount, Field Replaceable Sensor Filter, Up to 16´ Cable FEATURES/BENEFITS • Cable lengths from 4 to 16´ • Remote housing allows for flexibility sensing where space may be limited APPLICATIONS • Process system monitoring • Environmental chambers • Air economizers อ่านเพิ่ม
SERIES WHT , DWYER , WEATHER-RESISTANT HUMIDITY/TEMPERATURE TRANSMITTER SERIES WHT | DWYER WEATHER-RESISTANT HUMIDITY/TEMPERATURE TRANSMITTER Compact Housing, Sintered Filter2X FEATURES/BENEFITS • RH or RH and temperature outputs • Compact NEMA 3S construction APPLICATIONS • Air handling economizers • Air environment monitoring in agriculture or livestock cultivation houses อ่านเพิ่ม