BELIMO
BELIMO
Showing 113–128 of 389 resultsSorted by popularity
Rotary actuator for ball valves
• Nominal torque 20 Nm
• Nominal voltage AC 230 V
• Control Open-close, 3-point
• With integrated auxiliary switch
Modulating rotary actuator for ball
valves
• Nominal torque 20 Nm
• Nominal voltage AC/DC 24 V
• Control Modulating DC (0)2…10 V
• Position feedback DC 2…10 V
• Running time motor 35 s
Rotary actuator with emergency control function for ball valves
• Nominal torque 20 Nm
• Nominal voltage AC/DC 24 V
• Control Open-close
• Deenergised closed (NC)
Rotary actuator with emergency control function for ball valves
• Nominal torque 20 Nm
• Nominal voltage AC/DC 24 V
• Control Open-close
• with 2 integrated auxiliary switches
• Deenergised closed (NC)
Modulating rotary actuator with emergency control function for ball valves
• Nominal torque 20 Nm
• Nominal voltage AC/DC 24 V
• Control Modulating DC (0)2…10 V
• Position feedback DC 2…10 V
• Deenergised closed (NC)
Modulating rotary actuator with emergency control function for ball valves
• Nominal torque 20 Nm
• Nominal voltage AC/DC 24 V
• Control Modulating DC (0)2…10 V
• Position feedback DC 2…10 V
• with 2 integrated auxiliary switches
• Deenergised closed (NC)
Rotary actuator with emergency control function for ball valves
• Nominal torque 20 Nm
• Nominal voltage AC 24…240 V / DC 24…125 V
• Control Open-close
• Deenergised closed (NC)
Rotary actuator with emergency control function for ball valves
• Nominal torque 20 Nm
• Nominal voltage AC 24…240 V / DC 24…125 V
• Control Open-close
• with 2 integrated auxiliary switches
• Deenergised closed (NC)
Globe valve, 2-way, Flange, PN 16
• For closed cold and warm water systems
• For water-side modulating control of air-handling and heating systems
Globe valve, 2-way, Flange, PN 6
• For closed cold and warm water systems
• For water-side modulating control of air-handling and heating systems
Globe valve, 3-way, Flange, PN 16
• For closed cold and warm water systems
• For water-side modulating control of air-handling and heating systems
Globe valve, 3-way, Flange, PN 6
• For closed cold and warm water systems
• For water-side modulating control of air-handling and heating systems
Globe valve actuator with emergency control function for 2-way and 3-way globe valves
• Actuating force 2000 N
• Nominal voltage AC 24 V
• Control 3-point
• Nominal stroke 32 mm
• Design life SuperCaps: 15 years
Modulating globe valve actuator for 2-way and 3-way globe valves
• Actuating force 2000 N
• Nominal voltage AC/DC 24 V
• Control modulating DC (0)2…10 V
• Nominal stroke 32 mm
• Design life SuperCaps: 15 years
Modulating globe valve actuator for 2-way and 3-way globe valves
• Actuating force 2000 N
• Nominal voltage AC/DC 24 V
• Control modulating DC (0)0.5…10 V
• Nominal stroke 32 mm
• Design life SuperCaps: 15 years
Globe valve actuator with emergency control function for 2-way and 3-way globe valves
• Actuating force 2000 N
• Nominal voltage AC 230 V
• Control 3-point
• Nominal stroke 32 mm