Siemens VPD..MiniCombiValves (MCV)

Siemens VPD..MiniCombiValves (MCV)

Radiator valves featuring integrated differential pressure control for
2-pipe heating systems, fan coils and chilled ceiling systems
? Automatic flow limitation under all operating conditions
? Straightforward design of plant with no need for safety margins
? Thanks to MCV no hydraulic balancing within the zone required
? No additional line balancing valves required
? No noise problems
? Integrated presetting of kv-values
? DIN DN 10 and DN 15
? Valve bodies made of brass, mat nickel-plated
? Internally and externally threaded (Rp/R) conforming to ISO 7-1
? Can be combined with RTN.. thermostatic, STA..3.. electrothermal and SSA..
electromotoric actuators

 

สินค้าที่เกี่ยวข้อง

Siemens MXG462S..Modulating control valve with magnetic actuator‚ PN16

 

Short positioning time (< 2 s), high-resolution stroke (1 : 1000)
∂ Selectable valve characteristic: equal-percentage or linear
∂ High rangeability
∂ Operating voltage AC / DC 24 V
∂ Selectable standard signal inputs DC 0/2…10 V or DC 0/4…20 mA
∂ DC 0…20 V Phs phase-cut signal input for Staefa controllers
∂ Indication of operating state, visible from the outside
∂ Wear-free inductive stroke measurement
∂ Low friction, robust and maintenance-free
∂ Spring return facility: A↑ AB closed when de-energized
∂ Positioning control, position feedback and manual control
∂ Parts in contact with medium in CrNi steel
∂ MXG462S50-30 applications with demineralized water upon request

Siemens QFM21.. Duct sensor for rel. humidity / temperature

Device type QFM21..
Designation Duct sensors for humidity and
temperature
Product range SymaroTM

Room sensors
QFA41…
for relative humidity and temperature with calibration certificates
• Operating voltage AC 24 V / DC 13.5…35 V
• Signal output DC 0…10 V / 4…20 mA for relative humidity and temperature
• Very high measuring accuracy across the entire measuring range
• Capacitive humidity measurement
• Recalibration service
• Test function for loop test
• Range of use −40…+70 °C / 0…100 % r. h. with LCD display −25…+70 °C / 0…100 % r. h.
Use
The QFA41… sensor is used in ventilation and air conditioning plants requiring:
• Very high accuracy and reliability for measuring relative humidity and temperature
• Regular recalibration and readjustment of the sensors
Examples:
• Storage and production facilities in the paper, textiles, pharmaceutical, chemical, electronics industries, etc.
• Laboratories
• Hospitals
• Computer centers
• Greenhouses

Modulating control valves with magnetic actuator,PN 16
MVF461H..
for hot water, high temperature hot water and steam
• Short positioning time (<2 s), high resolution (1 : 1000)
• Selectable valve characteristic: Equal-percentage or linear
• High rangeability
• Selectable standard interface DC 0/2…10 V or DC 0/4…20 mA
• Phase-cut signal input for Staefa controllers
• Position control and position feedback signal
• Wear-free inductive stroke measurement
• Spring return facility: A → AB closed when deenergized
• Low friction, robust and maintenance-free

Modulating refrigerant valves with magnetic actuator, PS45
MVL661..-..
Hermetically sealed, for safety refrigerants
· One valve type for expansion, hot-gas and suction throttle applications
· Hermetically sealed towards outside
· Selectable standard interface DC 0/2…10 V or DC 0/4…20 mA
· High resolution and control accuracy
· Precise positioning control and position feedback signal
· Short positioning time (< 1 s)
· Closed when deenergized
· Robust and maintenance-free
· Six valve sizes with kvs values from 0.25 to 12 m³/h
Use
The MVL661..-.. refrigerant valve is designed for modulating control of refrigerant
circuits including chillers and heat pumps. It can be used in expansion, hot-gas and
suction throttle applications as well as with all commonly used safety refrigerants (R22,
R134a, R227ea, R404A, R407C, R410A, etc.) and R744 (CO2).

 

Universal controller with P or PI action for heating, ventilation and air conditioning. 

Auxiliary functions

  • PI limiter function (absolute and relative limit)
  • Remote setpoint
  • Setpoint compensation
  • Winter/summer mode changeover (analogue or digital input)
  • Cascade control
  • Maximum priority for cooling / dehumidifying