You are here:

Siemens VPP46..Combi valves (PICV) PN25, externally threaded

Siemens VPP46..Combi valves (PICV) PN25, externally threaded

systems
 With integrated differential pressure controller
 DN 10…DN32: Valve body made of dezincification resistant hot-pressed
brass (DZR)
 DN 40…DN 50: Housing made of spheroidal graphite iron
 Volumetric flow 30… 11500 l/h,
 Differential pressure range 15…600 kPa
 Internally threaded Rp conforming to ISO 7-1
 Externally threaded G conforming to ISO 228-1
 Version with pressure test points for Δp measurement (optional)
 Can be equipped with electro thermal or electromotive actuators
 SSA.. (3-position or DC 0…10 V)
 STA..3../STP..3.. (2-position or PDM)
 STA63../STP63.. (DC 0…10 V)
 SAY..1P03 (3-position or DC 0…10 V)

สินค้าที่เกี่ยวข้อง

Siemens VPI46..Q,,Combi valves (PICV) PN25, externally threaded

systems
 With integrated differential pressure controller
 DN 10…DN32: Valve body made of dezincification resistant hot-pressed
brass (DZR)
 DN 40…DN 50: Housing made of spheroidal graphite iron
 Volumetric flow 30… 11500 l/h,
 Differential pressure range 15…600 kPa
 Internally threaded Rp conforming to ISO 7-1
 Externally threaded G conforming to ISO 228-1
 Version with pressure test points for Δp measurement (optional)
 Can be equipped with electro thermal or electromotive actuators
 SSA.. (3-position or DC 0…10 V)
 STA..3../STP..3.. (2-position or PDM)
 STA63../STP63.. (DC 0…10 V)
 SAY..1P03 (3-position or DC 0…10 V)

Siemens MXG461S..Modulating control valves with magnetic actuator‚ PN 16

Fast positioning time (<2 s), high-resolution stroke (1 : 1000)
∂ Selectable valve characteristic: equal-percentage or linear
∂ High rangeability
∂ Operating voltage AC/ DC 24 V
∂ Switch-selected control signal DC 0/2…10 V or DC 4…20 mA
∂ Wear-free inductive stroke measurement
∂ Robust, no maintenance required
∂ Spring-return function: A ↑ AB closed when de-energized
∂ Positioning control, position feedback and manual control
∂ Parts in contact with medium in CrNi steel
∂ Applications with demineralized water upon request

Siemens MXF461.. Modulating control valves with magnetic actuators, PN 16

Fast positioning time (<2 s), high-resolution stroke (1 : 1000), high rangeability
· Equal-percentage or linear valve characteristic (user-selected)
· Operating voltage AC / DC 24 V
· Switch-selected control signal DC 0/2…10 V or DC 4…20 mA
· DC 0…20 V phase cut control signal with SEZ91.6 external interface
· Indication of operating state, position feedback and manual control
· Wear-free inductive stroke measurement
· Fail-safe feature: A ® AB closed when de-energized
· Low friction, robust, no maintenance required

Modulating refrigerant valves with magnetic actuator, PS45
MVL661..-..
Hermetically sealed, for safety refrigerants
· One valve type for expansion, hot-gas and suction throttle applications
· Hermetically sealed towards outside
· Selectable standard interface DC 0/2…10 V or DC 0/4…20 mA
· High resolution and control accuracy
· Precise positioning control and position feedback signal
· Short positioning time (< 1 s)
· Closed when deenergized
· Robust and maintenance-free
· Six valve sizes with kvs values from 0.25 to 12 m³/h
Use
The MVL661..-.. refrigerant valve is designed for modulating control of refrigerant
circuits including chillers and heat pumps. It can be used in expansion, hot-gas and
suction throttle applications as well as with all commonly used safety refrigerants (R22,
R134a, R227ea, R404A, R407C, R410A, etc.) and R744 (CO2).

 

SIEMENS
Modulating refrigerant valves with magnetic actuator‚ PS43
M3FB..LX..

Soldered connection‚ hermetically sealed

•Modulating control valve for hot-gas applications for capacity control of refrigeration units and heat recovery systems
•For organic safety refrigerants
•AC 24 V operating voltage or power signal DC 0…20 V Phs (phase cut)
•Selectable electrical interface ZM.. with DC 0…10 V, DC 4…20 mA or DC 0…20 V Phs positioning signal
•High resolution and control accuracy
•Short positioning time (< 1 s)
•Port AB  A closed when de-energized
•Robust and maintenance-free
•DN 15…32, kvs values 0.6…12 m3/h

 

Universal controller with P or PI action for heating, ventilation and air conditioning. 

Auxiliary functions

  • PI limiter function (absolute and relative limit)
  • Remote setpoint
  • Setpoint compensation
  • Winter/summer mode changeover (analogue or digital input)
  • Cascade control
  • Maximum priority for cooling / dehumidifying