You are here:

Siemens ZM100/A Electronic connection for valves with magnetic actuator

Siemens ZM100/A Electronic connection for valves with magnetic actuator

Terminal housing for control of valves with mag-netic actuator

Control with choice of positioning signals or direct control
AC 24 V
DC 0…10 V
DC 4…20 mA
DC 0…20 V Phs

สินค้าที่เกี่ยวข้อง

Siemens MXG462S..Modulating control valve with magnetic actuator‚ PN16

 

Short positioning time (< 2 s), high-resolution stroke (1 : 1000)
∂ Selectable valve characteristic: equal-percentage or linear
∂ High rangeability
∂ Operating voltage AC / DC 24 V
∂ Selectable standard signal inputs DC 0/2…10 V or DC 0/4…20 mA
∂ DC 0…20 V Phs phase-cut signal input for Staefa controllers
∂ Indication of operating state, visible from the outside
∂ Wear-free inductive stroke measurement
∂ Low friction, robust and maintenance-free
∂ Spring return facility: A↑ AB closed when de-energized
∂ Positioning control, position feedback and manual control
∂ Parts in contact with medium in CrNi steel
∂ MXG462S50-30 applications with demineralized water upon request

Siemens MXG461B.. Modulating control valves with magnetic actuators, PN 16

Short positioning time (< 2 s), high resolution (1 : 1000)
? Selectable valve characteristic: equal-percentage or linear
? High rangeability
? Operating voltage AC / DC 24 V
? Selectable standard signal inputs DC 0/2…10 V or DC 0/4…20 mA
? DC 0…20 V Phs phase-cut signal input for Staefa controllers
? Indication of operating state, visible from the outside
? Accurate position feedback signal by inductive stroke measurement
? Spring return facility: A ? AB closed when deenergized
? Low friction, robust and maintenance-free
? Including fittings

Siemens MXF461.. Modulating control valves with magnetic actuators, PN 16

Fast positioning time (<2 s), high-resolution stroke (1 : 1000), high rangeability
· Equal-percentage or linear valve characteristic (user-selected)
· Operating voltage AC / DC 24 V
· Switch-selected control signal DC 0/2…10 V or DC 4…20 mA
· DC 0…20 V phase cut control signal with SEZ91.6 external interface
· Indication of operating state, position feedback and manual control
· Wear-free inductive stroke measurement
· Fail-safe feature: A ® AB closed when de-energized
· Low friction, robust, no maintenance required

Room sensors
QFA41…
for relative humidity and temperature with calibration certificates
• Operating voltage AC 24 V / DC 13.5…35 V
• Signal output DC 0…10 V / 4…20 mA for relative humidity and temperature
• Very high measuring accuracy across the entire measuring range
• Capacitive humidity measurement
• Recalibration service
• Test function for loop test
• Range of use −40…+70 °C / 0…100 % r. h. with LCD display −25…+70 °C / 0…100 % r. h.
Use
The QFA41… sensor is used in ventilation and air conditioning plants requiring:
• Very high accuracy and reliability for measuring relative humidity and temperature
• Regular recalibration and readjustment of the sensors
Examples:
• Storage and production facilities in the paper, textiles, pharmaceutical, chemical, electronics industries, etc.
• Laboratories
• Hospitals
• Computer centers
• Greenhouses

SIEMENS
Modulating refrigerant valves with magnetic actuator‚ PS43
M3FB..LX..

Soldered connection‚ hermetically sealed

•Modulating control valve for hot-gas applications for capacity control of refrigeration units and heat recovery systems
•For organic safety refrigerants
•AC 24 V operating voltage or power signal DC 0…20 V Phs (phase cut)
•Selectable electrical interface ZM.. with DC 0…10 V, DC 4…20 mA or DC 0…20 V Phs positioning signal
•High resolution and control accuracy
•Short positioning time (< 1 s)
•Port AB  A closed when de-energized
•Robust and maintenance-free
•DN 15…32, kvs values 0.6…12 m3/h

 

Universal controller with P or PI action for heating, ventilation and air conditioning. 

Auxiliary functions

  • PI limiter function (absolute and relative limit)
  • Remote setpoint
  • Setpoint compensation
  • Winter/summer mode changeover (analogue or digital input)
  • Cascade control
  • Maximum priority for cooling / dehumidifying