BELIMO

Zone valve, 2-way, Internal thread
• For closed cold and warm water systems
• For shut-off functions and modulating controls
on the water side of air-handling units and
heating systems.
• Snap-assembly of the actuator
• kvs variable

Changeover zone valve, 3-way, Internal thread
• For closed cold and warm water systems
• For switching functions and 2-point controls
on the water side of air-handling units and
heating systems
• Snap-assembly of the actuator

Fan Coil Unit, 2-way, Internal thread

Rotary actuator for butterfly valves
• Nominal torque 160 Nm
• Nominal voltage AC 24…240 V / DC 24…125 V
• Control Open-close, 3-point
• with 2 integrated auxiliary switches

Rotary actuator for butterfly valves
• Torque motor 160 Nm
• Nominal voltage AC 24…240 V / DC 24…125 V
• Control Open/close, 3-point
• With 2 integrated auxiliary switches

Rotary actuator fail-safe for butterfly valves
• Torque motor 160 Nm
• Nominal voltage AC 24…240 V / DC 24…125 V
• Control modulating, communicative, hybrid
• With 2 integrated auxiliary switches
• Conversion of sensor signals
• Communication via BACnet MS/TP, Modbus
RTU, Belimo-MP-Bus or conventional control

Rotary actuator fail-safe for butterfly valves
• Torque motor 160 Nm
• Nominal voltage AC 24…240 V / DC 24…125 V
• Control modulating, communicative, hybrid
• With 2 integrated auxiliary switches
• Conversion of sensor signals
• Communication via BACnet MS/TP, Modbus
RTU, Belimo-MP-Bus or conventional control

Rotary actuator fail-safe for butterfly valves
• Torque motor 160 Nm
• Nominal voltage AC 24…240 V / DC 24…125 V
• Control modulating, communicative, hybrid
• With 2 integrated auxiliary switches
• Conversion of sensor signals
• Communication via BACnet MS/TP, Modbus
RTU, Belimo-MP-Bus or conventional control

Rotary actuator fail-safe for butterfly valves
• Torque motor 160 Nm
• Nominal voltage AC 24…240 V / DC 24…125 V
• Control modulating, communicative, hybrid
• With 2 integrated auxiliary switches
• Conversion of sensor signals
• Communication via BACnet MS/TP, Modbus
RTU, Belimo-MP-Bus or conventional control

Rotary actuator fail-safe for butterfly valves
• Torque motor 160 Nm
• Nominal voltage AC 24…240 V / DC 24…125 V
• Control modulating, communicative, hybrid
• With 2 integrated auxiliary switches
• Conversion of sensor signals
• Communication via BACnet MS/TP, Modbus
RTU, Belimo-MP-Bus or conventional control

Leakage switch
For detection of liquid leakage. Designed for
alarm, control and monitoring applications of
containers, false floors, suspended ceilings or
rooms for preventing unintended leackage.
With changeover relay contact for control of
control and display systems or for series
connection with a valve to interrupt the water
flow directly. Provision takes place
automatically after drying off of the contacts.
IP65 / NEMA 4 rated enclosure.

Duct sensor CO₂ / Temperature

For measuring CO₂, with integrated passive
temperature sensor. Dual channel CO₂
technology. IP65 / NEMA 4X rated enclosure.

Duct sensor CO₂ / Temperature

For measuring CO₂, with integrated passive
temperature sensor. Dual channel CO₂
technology. IP65 / NEMA 4X rated enclosure.

Duct sensor CO₂ / VOC / CO₂+VOC mix /
Temperature

Active sensor (0…10 V) for measuring CO₂ and
VOC or with integrated temperature sensor. See
options below for integrated sensors. Dual
channel CO₂ technology. IP65 / NEMA 4X rated
enclosure.

Duct sensor CO₂ / Temperature

Active sensor (0…10 V) for measuring CO₂, with
integrated temperature sensor. Dual channel
CO₂ technology. IP65 / NEMA 4X rated
enclosure.

  • Duct sensor CO₂ / Humidity / Temperature
  • Active sensor (0…10 V) for measuring CO₂, temperature and humidity.
  • Dual channel CO₂ technology. Optionally available with LCD display. IP65 / NEMA 4X rated enclosure.