BELIMO

Fail-Safe actuator used in typical Fire and Smoke
damper applications
• Torque motor 30 in-lb [3.5 Nm]
• Nominal voltage AC 230 V
• Control On/Off
• @ 350°F [177°C] for 30 min
• 15 s, <15 s Motor/Fail-safe
• 2x SPST

Characterised control valve with thermal energy
meter, sensor-operated flow or power control,
power and energy monitoring function, 2-way,
internal and external thread, PN 25
• Nominal voltage AC/DC 24 V
• Control modulating, communicative, hybrid
• For closed cold and warm water systems
• For modulating control of air-handling and
heating systems on the water side
• Ethernet 10/100 Mbit/s, TCP/IP, integrated
web server
• Communication via BACnet, Modbus, Belimo
MP-Bus or conventional control
• PoE (Power over Ethernet) Power supply
possible
• Conversion of sensor signals
• Glycol monitoring
• Power control, flow control, position control
and differential pressure control

Characterised control valve with thermal
energy meter, certified for heating
applications according to MID, fulfills the
requirements of EN 1434. Sensor-operated
flow rate or power control, power and energy
monitoring function, 2-way, internal thread,
PN 25
• Nominal voltage AC/DC 24 V
• Control modulating, communicative, hybrid
• For closed cold and warm water systems
• For modulating control of air-handling and
heating systems on the water side
• Ethernet 10/100 Mbit/s, TCP/IP, integrated
web server
• Communication via BACnet, Modbus, Belimo
MP-Bus or conventional control
• PoE (Power over Ethernet) Power supply
possible
• Conversion of sensor signals

Characterised control valve with sensoroperated flow rate or power control, power and
energy-monitoring function, 2-way, Flange,
PN 16 (Energy Valve)
• Nominal voltage AC/DC 24 V
• Control modulating, communicative, hybrid,
Cloud
• For closed cold and warm water systems
• For modulating control of air-handling and
heating systems on the water side
• Ethernet 10/100 Mbit/s, TCP/IP, integrated
web server
• Communication via BACnet, Modbus, Belimo
MP-Bus or conventional control
• optional Belimo Cloud connection
• Glycol monitoring

Characterised control valve with thermal energy
meter, sensor-operated flow or power control,
power and energy monitoring function, 2-way,
internal and external thread, PN 25

• Nominal voltage AC/DC 24 V
• Control modulating, communicative, hybrid
• For closed cold and warm water systems
• For modulating control of air-handling and
heating systems on the water side
• Ethernet 10/100 Mbit/s, TCP/IP, integrated
web server
• Communication via BACnet, Modbus, Belimo
MP-Bus or conventional control
• PoE (Power over Ethernet) Power supply
possible
• Conversion of sensor signals
• Glycol monitoring
• Power control, flow control, posit

Characterised control valve with sensoroperated flow rate or power control with failsafe, power and energy-monitoring function, 2-
way, Flange, PN 16 (Energy Valve)
• Nominal voltage AC/DC 24 V
• Control modulating, communicative, hybrid,
Cloud
• For closed cold and warm water systems
• For modulating control of air-handling and
heating systems on the water side
• Ethernet 10/100 Mbit/s, TCP/IP, integrated
web server
• Communication via BACnet, Modbus, Belimo
MP-Bus or conventional control
• optional Belimo Cloud connection
• Glycol monitoring

Characterised control valve with sensoroperated flow control, 2-way, Internal and
external thread, PN 25 (EPIV)
• Nominal voltage AC/DC 24 V
• Control modulating, communicative, hybrid
• For closed cold and warm water systems
• For modulating control of air-handling and
heating systems on the water side
• Communication via BACnet MS/TP, Modbus
RTU, Belimo-MP-Bus or conventional control
• Conversion of active sensor signals and
switching contacts
• Measurement of the fluid temperature

Characterised control valve with sensoroperated flow control, 2-way, Flange, PN 16
(EPIV)
• Nominal voltage AC/DC 24 V
• Control modulating, communicative, hybrid
• For closed cold and warm water systems
• For modulating control of air-handling and
heating systems on the water side
• Communication via BACnet MS/TP, Modbus
RTU, Belimo-MP-Bus or conventional control
• Conversion of active sensor signals and
switching contacts

Characterised control valve with sensoroperated flow control, 2-way, Flange, PN 16
(EPIV)
• Nominal voltage AC/DC 24 V
• Control modulating, communicative
• For closed cold and warm water systems
• For modulating control of air-handling and
heating systems on the water side
• Communication via Belimo MP-Bus or
conventional control
• Conversion of active sensor signals and
switching contacts

Characterised control valve with sensoroperated flow control with fail-safe, 2-way,
Internal and external thread, PN 25 (EPIV)
• Nominal voltage AC/DC 24 V
• Control modulating, communicative, hybrid
• For closed cold and warm water systems
• For modulating control of air-handling and
heating systems on the water side
• Communication via Belimo MP-Bus or
conventional control
• Conversion of active sensor signals and
switching contacts
• Measurement of the fluid temperature

Characterised control valve with sensoroperated flow control with fail-safe, 2-way,
Flange, PN 16 (EPIV)
• Nominal voltage AC/DC 24 V
• Control modulating, communicative
• For closed cold and warm water systems
• For modulating control of air-handling and
heating systems on the water side
• Communication via Belimo MP-Bus or
conventional control
• Conversion of active sensor signals and
switching contacts

PI Zone Valve, 2-way, Internal thread
• For closed cold and warm water systems
• For modulating control of air-handling and
heating systems on the water side
• Snap-assembly of the actuator

Rotary actuator for butterfly valves
• Nominal torque 160 Nm
• Nominal voltage AC 24…240 V / DC 24…125 V
• Control modulating, communicative
• with 2 integrated auxiliary switches
• Conversion of sensor signals
• Communication via BACnet MS/TP,
Belimo MP-Bus or conventional control

PI flow limiter valve, 2-way, Internal thread
• For closed cold water systems
• For water-side on/off control of fan coil and
cooling ceilings

Rotary actuator for butterfly valves
• Nominal torque 160 Nm
• Nominal voltage AC 24…240 V / DC 24…125 V
• Control Open-close, 3-point
• with 2 integrated auxiliary switches