Internal thread

You are here:

Internal thread

EV..R+BAC

Characterised control valve with sensor-operated flow rate or power control, power and energy-monitoring function, 2-way, Internal thread, PN 16 (Energy Valve)

• Nominal voltage AC/DC 24 V
• Control modulating, communicative
• For closed cold and warm water systems
• For modulating control of air-handling and heating systems on the water side
• Ethernet 10/100 Mbit/s, TCP/IP, integrated web server
• Communication via BACnet IP, BACnet MS/TP, Modbus TCP, Modbus RTU, Belimo MP-Bus or conventional control

EV..R+KBAC

Characterised control valve with sensor-operated flow rate or power control, power and energy-monitoring function, 2-way, Internal thread, PN 16 (Energy Valve),

• Nominal voltage AC/DC 24 V
• Control modulating, communicative
• For closed cold and warm water systems
• For modulating control of air-handling and heating systems on the water side
• Ethernet 10/100 Mbit/s, TCP/IP, integrated web server
• Communication via BACnet IP, BACnet MS/TP, Modbus TCP, Modbus RTU, Belimo MP-Bus or conventional control
• Design life SuperCaps: 15 years

EP..R+MP

Communicative characterised control valve with sensor-operated flow control, 2-way, internal thread (EPIV)
• Nominal voltage AC/DC 24 V
• Control Modulating
• For closed cold and warm water systems
• For modulating control of air-handling and heating systems on the water side
• Communication via Belimo MP-Bus or conventional control
• Conversion of active sensor signals and switching contacts

EP..R+KMP

Communicative characterised control valve with sensor-operated flow control and emergency control function, 2-way, internal thread (EPIV)
• Nominal voltage AC/DC 24 V
• Control Modulating
• For closed cold and warm water systems
• For modulating control of air-handling and heating systems on the water side
• Communication via Belimo MP-Bus or conventional control
• Conversion of active sensor signals and switching contacts
• Design life SuperCaps: 15 years

R3..xx-S..
Characterised control valve, 3-way,
Internal thread
• For closed cold and warm water systems
• For modulating water-side control of air handling units and heating systems
• Air bubble-tight (control path A – AB)

PI Zone Valve, 2-way, Internal thread
• For closed cold and warm water systems
• For modulating control of air-handling and
heating systems on the water side
• Snap-assembly of the actuator

PI flow limiter valve, 2-way, Internal thread
• For closed cold water systems
• For water-side on/off control of fan coil and
cooling ceilings

Zone valve, 2-way, Internal thread
• For closed cold and warm water systems
• For shut-off functions and modulating controls
on the water side of air-handling units and
heating systems.
• Snap-assembly of the actuator
• kvs variable

Changeover zone valve, 3-way, Internal thread
• For closed cold and warm water systems
• For switching functions and 2-point controls
on the water side of air-handling units and
heating systems
• Snap-assembly of the actuator

Fan Coil Unit, 2-way, Internal thread

BELIMO PI flow limiter valve เป็นวาล์วควบคุมทิศทางแบบ 2 ทาง ชนิดเกลียวใน ที่รวมฟังก์ชันการควบคุมการเปิด/ปิด (On/Off) และการจำกัดอัตราการไหลไว้ในตัวเดียว

จุดเด่นสำคัญ:

  • อัตราการไหลคงที่ (Constant Flow): รักษาอัตราการไหลให้สม่ำเสมอในช่วงความดันแตกต่าง 20…280 kPa แม้ความดันในระบบจะเปลี่ยนแปลง
  • การปิดสนิท: ปิดสนิทแบบ Air-bubble tight (Leakage rate A ตามมาตรฐาน EN 12266-1)
  • ไม่ต้องบำรุงรักษา: ตัววาล์วและหัวขับถูกออกแบบมาให้ไม่ต้องบำรุงรักษาตลอดอายุการใช้งาน (Maintenance-free)

ข้อมูลทางเทคนิค:

  • ขนาด (DN): 15, 20 และ 25 (PN 25)
  • อุณหภูมิของเหลว: 2…60°C (เหมาะสำหรับระบบน้ำเย็นแบบปิด)
  • วัสดุตัวเรือน: ทองเหลือง (สำหรับ DN 15, 20) และทองเหลืองชุบนิกเกิล (สำหรับ DN 25)
  • การติดตั้ง: ติดตั้งได้ทั้งแนวตั้งและแนวนอน (ห้ามติดตั้งแบบแกนชี้ลง)

การใช้งาน: เหมาะสำหรับควบคุมน้ำในระบบ HVAC เช่น Fan Coil Units และ Cooling Ceilings