EP..R+KMP ,Communicative characterised control valve with sensor-operated flow control and emergency control function, 2-way, internal thread ,EPIV

EP..R+KMP

Communicative characterised control valve with sensor-operated flow control and emergency control function, 2-way, internal thread (EPIV)
• Nominal voltage AC/DC 24 V
• Control Modulating
• For closed cold and warm water systems
• For modulating control of air-handling and heating systems on the water side
• Communication via Belimo MP-Bus or conventional control
• Conversion of active sensor signals and switching contacts
• Design life SuperCaps: 15 years

EP..R+MP ,Communicative characterised control valve with sensor-operated flow control, 2-way, internal thread ,EPIV

EP..R+MP

Communicative characterised control valve with sensor-operated flow control, 2-way, internal thread (EPIV)
• Nominal voltage AC/DC 24 V
• Control Modulating
• For closed cold and warm water systems
• For modulating control of air-handling and heating systems on the water side
• Communication via Belimo MP-Bus or conventional control
• Conversion of active sensor signals and switching contacts

EV..R+KBAC ,Characterised control valve with sensor-operated flow rate or power control, power and energy-monitoring function, 2-way, Internal thread, PN 16 (Energy Valve),

EV..R+KBAC

Characterised control valve with sensor-operated flow rate or power control, power and energy-monitoring function, 2-way, Internal thread, PN 16 (Energy Valve),

• Nominal voltage AC/DC 24 V
• Control modulating, communicative
• For closed cold and warm water systems
• For modulating control of air-handling and heating systems on the water side
• Ethernet 10/100 Mbit/s, TCP/IP, integrated web server
• Communication via BACnet IP, BACnet MS/TP, Modbus TCP, Modbus RTU, Belimo MP-Bus or conventional control
• Design life SuperCaps: 15 years

EV..R+BAC ,Characterised control valve with sensor-operated flow rate or power control, power and energy-monitoring function, 2-way, Internal thread, PN 16 (Energy Valve)

EV..R+BAC

Characterised control valve with sensor-operated flow rate or power control, power and energy-monitoring function, 2-way, Internal thread, PN 16 (Energy Valve)

• Nominal voltage AC/DC 24 V
• Control modulating, communicative
• For closed cold and warm water systems
• For modulating control of air-handling and heating systems on the water side
• Ethernet 10/100 Mbit/s, TCP/IP, integrated web server
• Communication via BACnet IP, BACnet MS/TP, Modbus TCP, Modbus RTU, Belimo MP-Bus or conventional control