- Home
- SIEMENS
- Valves and actuators
- Siemens MVF461H.. Modulating control valves with magnetic actuator, PN 16
Siemens MVF461H.. Modulating control valves with magnetic actuator, PN 16
Siemens MVF461H.. Modulating control valves with magnetic actuator, PN 16
• Short positioning time (<2 s), high resolution (1 : 1000)
• Selectable valve characteristic: Equal-percentage or linear
• High rangeability
• Selectable standard interface DC 0/2…10 V or DC 0/4…20 mA
• Phase-cut signal input for Staefa controllers
• Position control and position feedback signal
• Wear-free inductive stroke measurement
• Spring return facility: A → AB closed when deenergized
• Low friction, robust and maintenance-free
สินค้าที่เกี่ยวข้อง
Siemens VPP46..Combi valves (PICV) PN25, externally threaded
systems
With integrated differential pressure controller
DN 10…DN32: Valve body made of dezincification resistant hot-pressed
brass (DZR)
DN 40…DN 50: Housing made of spheroidal graphite iron
Volumetric flow 30… 11500 l/h,
Differential pressure range 15…600 kPa
Internally threaded Rp conforming to ISO 7-1
Externally threaded G conforming to ISO 228-1
Version with pressure test points for Δp measurement (optional)
Can be equipped with electro thermal or electromotive actuators
SSA.. (3-position or DC 0…10 V)
STA..3../STP..3.. (2-position or PDM)
STA63../STP63.. (DC 0…10 V)
SAY..1P03 (3-position or DC 0…10 V)
Siemens MXG461.. Modulating control valves with magnetic actuators, PN 16
Fast positioning time (<2 s), high-resolution stroke (1 : 1000), high rangeability
? Equal-percentage or linear valve characteristic (user-selected)
? Operating voltage AC / DC 24 V
? Switch-selected control signal DC 0/2…10 V or DC 4…20 mA
? DC 0…20 V phase cut control signal with SEZ91.6 external interface
? Indication of operating state, position feedback and manual control
? Wear-free inductive stroke measurement
? Fail-safe feature: A ? AB closed when de-energized
? Low friction, robust, no maintenance required
Siemens MXF461.. Modulating control valves with magnetic actuators, PN 16
Fast positioning time (<2 s), high-resolution stroke (1 : 1000), high rangeability
· Equal-percentage or linear valve characteristic (user-selected)
· Operating voltage AC / DC 24 V
· Switch-selected control signal DC 0/2…10 V or DC 4…20 mA
· DC 0…20 V phase cut control signal with SEZ91.6 external interface
· Indication of operating state, position feedback and manual control
· Wear-free inductive stroke measurement
· Fail-safe feature: A ® AB closed when de-energized
· Low friction, robust, no maintenance required
Siemens QFM31..Duct sensors for rel. humidity / temperature for demanding requirements
• Operating voltage AC 24 V / DC 13.5…35 V
• Signal output DC 0…10 V / 4…20 mA for relative humidity and temperature
• Very high measuring accuracy across the entire measuring range
• Function test
• Capacitive humidity measurement
• Range of use −40…+70 °C / 0…100 % r. h. with LCD display −25…+70 °C / 0…100 % r.h.
P6..W..EV-KBAC
Characterised control valve with sensor-operated flow rate or power control, power and energy-monitoring function, 2-way, Flange, PN 16 (Energy Valve), with emergency control function
• Nominal voltage AC/DC 24 V
• Control modulating, communicative
• For closed cold and warm water systems
• For modulating control of air-handling and heating systems on the water side
• Ethernet 10/100 Mbit/s, TCP/IP, integrated web server
• Communication via BACnet IP, BACnet MS/TP, Modbus TCP, Modbus RTU, Belimo MP-Bus or conventional control
• Design life SuperCaps: 15 years
SIEMENS
Modulating refrigerant valves with magnetic actuator‚ PS43
M3FB..LX..
Soldered connection‚ hermetically sealed
•Modulating control valve for hot-gas applications for capacity control of refrigeration units and heat recovery systems
•For organic safety refrigerants
•AC 24 V operating voltage or power signal DC 0…20 V Phs (phase cut)
•Selectable electrical interface ZM.. with DC 0…10 V, DC 4…20 mA or DC 0…20 V Phs positioning signal
•High resolution and control accuracy
•Short positioning time (< 1 s)
•Port AB A closed when de-energized
•Robust and maintenance-free
•DN 15…32, kvs values 0.6…12 m3/h

สั่งซื้อสินค้า