Fast positioning time (<2 s), high-resolution stroke (1 : 1000), high rangeability
? Equal-percentage or linear valve characteristic (user-selected)
? Operating voltage AC / DC 24 V
? Switch-selected control signal DC 0/2…10 V or DC 4…20 mA
? DC 0…20 V phase cut control signal with SEZ91.6 external interface
? Indication of operating state, position feedback and manual control
? Wear-free inductive stroke measurement
? Fail-safe feature: A ? AB closed when de-energized
? Low friction, robust, no maintenance required

สินค้าที่เกี่ยวข้อง

Siemens VPI46..Q,,Combi valves (PICV) PN25, externally threaded

systems
 With integrated differential pressure controller
 DN 10…DN32: Valve body made of dezincification resistant hot-pressed
brass (DZR)
 DN 40…DN 50: Housing made of spheroidal graphite iron
 Volumetric flow 30… 11500 l/h,
 Differential pressure range 15…600 kPa
 Internally threaded Rp conforming to ISO 7-1
 Externally threaded G conforming to ISO 228-1
 Version with pressure test points for Δp measurement (optional)
 Can be equipped with electro thermal or electromotive actuators
 SSA.. (3-position or DC 0…10 V)
 STA..3../STP..3.. (2-position or PDM)
 STA63../STP63.. (DC 0…10 V)
 SAY..1P03 (3-position or DC 0…10 V)

Siemens VPP46..Q,Combi valves (PICV) PN25, externally threaded

systems
 With integrated differential pressure controller
 DN 10…DN32: Valve body made of dezincification resistant hot-pressed
brass (DZR)
 DN 40…DN 50: Housing made of spheroidal graphite iron
 Volumetric flow 30… 11500 l/h,
 Differential pressure range 15…600 kPa
 Internally threaded Rp conforming to ISO 7-1
 Externally threaded G conforming to ISO 228-1
 Version with pressure test points for Δp measurement (optional)
 Can be equipped with electro thermal or electromotive actuators
 SSA.. (3-position or DC 0…10 V)
 STA..3../STP..3.. (2-position or PDM)
 STA63../STP63.. (DC 0…10 V)
 SAY..1P03 (3-position or DC 0…10 V)

Siemens VPI46…Combi valves (PICV) PN25, internally threaded

systems
 With integrated differential pressure controller
 DN 10…DN32: Valve body made of dezincification resistant hot-pressed
brass (DZR)
 DN 40…DN 50: Housing made of spheroidal graphite iron
 Volumetric flow 30… 11500 l/h,
 Differential pressure range 15…600 kPa
 Internally threaded Rp conforming to ISO 7-1
 Externally threaded G conforming to ISO 228-1
 Version with pressure test points for Δp measurement (optional)
 Can be equipped with electro thermal or electromotive actuators
 SSA.. (3-position or DC 0…10 V)
 STA..3../STP..3.. (2-position or PDM)
 STA63../STP63.. (DC 0…10 V)
 SAY..1P03 (3-position or DC 0…10 V)

Siemens MXF461.. Modulating control valves with magnetic actuators, PN 16

Fast positioning time (<2 s), high-resolution stroke (1 : 1000), high rangeability
· Equal-percentage or linear valve characteristic (user-selected)
· Operating voltage AC / DC 24 V
· Switch-selected control signal DC 0/2…10 V or DC 4…20 mA
· DC 0…20 V phase cut control signal with SEZ91.6 external interface
· Indication of operating state, position feedback and manual control
· Wear-free inductive stroke measurement
· Fail-safe feature: A ® AB closed when de-energized
· Low friction, robust, no maintenance required

Siemens QFM41.. Duct sensors for rel. humidity / temperature for demanding requirements, with calibration certificate

• Operating voltage AC 24 V / DC 13.5…35 V
• Signal output DC 0…10 V / 4…20 mA for relative humidity and temperature
• Very high measuring accuracy throughout the entire measuring range
• Capacitive humidity measurement
• Recalibration service
• Test function for loop test
• Range of use −40…+70 °C / 0…100 % r. h.

Universal controller with P or PI action for heating, ventilation and air conditioning. 

Auxiliary functions

  • PI limiter function (absolute and relative limit)
  • Remote setpoint
  • Setpoint compensation
  • Winter/summer mode changeover (analogue or digital input)
  • Cascade control
  • Maximum priority for cooling / dehumidifying