Short positioning time (< 2 s), high resolution (1 : 1000)
? Selectable valve characteristic: equal-percentage or linear
? High rangeability
? Operating voltage AC / DC 24 V
? Selectable standard signal inputs DC 0/2…10 V or DC 0/4…20 mA
? DC 0…20 V Phs phase-cut signal input for Staefa controllers
? Indication of operating state, visible from the outside
? Accurate position feedback signal by inductive stroke measurement
? Spring return facility: A ? AB closed when deenergized
? Low friction, robust and maintenance-free
? Including fittings

สินค้าที่เกี่ยวข้อง

Siemens VPI46..Q,,Combi valves (PICV) PN25, externally threaded

systems
 With integrated differential pressure controller
 DN 10…DN32: Valve body made of dezincification resistant hot-pressed
brass (DZR)
 DN 40…DN 50: Housing made of spheroidal graphite iron
 Volumetric flow 30… 11500 l/h,
 Differential pressure range 15…600 kPa
 Internally threaded Rp conforming to ISO 7-1
 Externally threaded G conforming to ISO 228-1
 Version with pressure test points for Δp measurement (optional)
 Can be equipped with electro thermal or electromotive actuators
 SSA.. (3-position or DC 0…10 V)
 STA..3../STP..3.. (2-position or PDM)
 STA63../STP63.. (DC 0…10 V)
 SAY..1P03 (3-position or DC 0…10 V)

Siemens VPP46..Combi valves (PICV) PN25, externally threaded

systems
 With integrated differential pressure controller
 DN 10…DN32: Valve body made of dezincification resistant hot-pressed
brass (DZR)
 DN 40…DN 50: Housing made of spheroidal graphite iron
 Volumetric flow 30… 11500 l/h,
 Differential pressure range 15…600 kPa
 Internally threaded Rp conforming to ISO 7-1
 Externally threaded G conforming to ISO 228-1
 Version with pressure test points for Δp measurement (optional)
 Can be equipped with electro thermal or electromotive actuators
 SSA.. (3-position or DC 0…10 V)
 STA..3../STP..3.. (2-position or PDM)
 STA63../STP63.. (DC 0…10 V)
 SAY..1P03 (3-position or DC 0…10 V)

Siemens VPD..MiniCombiValves (MCV)

Radiator valves featuring integrated differential pressure control for
2-pipe heating systems, fan coils and chilled ceiling systems
? Automatic flow limitation under all operating conditions
? Straightforward design of plant with no need for safety margins
? Thanks to MCV no hydraulic balancing within the zone required
? No additional line balancing valves required
? No noise problems
? Integrated presetting of kv-values
? DIN DN 10 and DN 15
? Valve bodies made of brass, mat nickel-plated
? Internally and externally threaded (Rp/R) conforming to ISO 7-1
? Can be combined with RTN.. thermostatic, STA..3.. electrothermal and SSA..
electromotoric actuators

 

Siemens QFM31..Duct sensors for rel. humidity / temperature for demanding requirements

• Operating voltage AC 24 V / DC 13.5…35 V
• Signal output DC 0…10 V / 4…20 mA for relative humidity and temperature
• Very high measuring accuracy across the entire measuring range
• Function test
• Capacitive humidity measurement
• Range of use −40…+70 °C / 0…100 % r. h. with LCD display −25…+70 °C / 0…100 % r.h.

P6..W..EV-BAC

Characterised control valve with sensor-operated flow rate or power control, power and energy-monitoring function, 2-way, Flange, PN 16 (Energy Valve)
• Nominal voltage AC/DC 24 V
• Control modulating, communicative
• For closed cold and warm water systems
• For modulating control of air-handling and heating systems on the water side
• Ethernet 10/100 Mbit/s, TCP/IP, integrated web server
• Communication via BACnet IP, BACnet MS/TP, Modbus TCP, Modbus RTU, Belimo MP-Bus or conventional control

 

SIEMENS
Modulating refrigerant valves with magnetic actuator‚ PS43
M3FB..LX..

Soldered connection‚ hermetically sealed

•Modulating control valve for hot-gas applications for capacity control of refrigeration units and heat recovery systems
•For organic safety refrigerants
•AC 24 V operating voltage or power signal DC 0…20 V Phs (phase cut)
•Selectable electrical interface ZM.. with DC 0…10 V, DC 4…20 mA or DC 0…20 V Phs positioning signal
•High resolution and control accuracy
•Short positioning time (< 1 s)
•Port AB  A closed when de-energized
•Robust and maintenance-free
•DN 15…32, kvs values 0.6…12 m3/h