You are here:

Siemens VPI46…Combi valves (PICV) PN25, internally threaded

Siemens VPI46…Combi valves (PICV) PN25, internally threaded

systems
 With integrated differential pressure controller
 DN 10…DN32: Valve body made of dezincification resistant hot-pressed
brass (DZR)
 DN 40…DN 50: Housing made of spheroidal graphite iron
 Volumetric flow 30… 11500 l/h,
 Differential pressure range 15…600 kPa
 Internally threaded Rp conforming to ISO 7-1
 Externally threaded G conforming to ISO 228-1
 Version with pressure test points for Δp measurement (optional)
 Can be equipped with electro thermal or electromotive actuators
 SSA.. (3-position or DC 0…10 V)
 STA..3../STP..3.. (2-position or PDM)
 STA63../STP63.. (DC 0…10 V)
 SAY..1P03 (3-position or DC 0…10 V)

สินค้าที่เกี่ยวข้อง

Siemens VPI46..Q,,Combi valves (PICV) PN25, externally threaded

systems
 With integrated differential pressure controller
 DN 10…DN32: Valve body made of dezincification resistant hot-pressed
brass (DZR)
 DN 40…DN 50: Housing made of spheroidal graphite iron
 Volumetric flow 30… 11500 l/h,
 Differential pressure range 15…600 kPa
 Internally threaded Rp conforming to ISO 7-1
 Externally threaded G conforming to ISO 228-1
 Version with pressure test points for Δp measurement (optional)
 Can be equipped with electro thermal or electromotive actuators
 SSA.. (3-position or DC 0…10 V)
 STA..3../STP..3.. (2-position or PDM)
 STA63../STP63.. (DC 0…10 V)
 SAY..1P03 (3-position or DC 0…10 V)

Siemens MXG461B.. Modulating control valves with magnetic actuators, PN 16

Short positioning time (< 2 s), high resolution (1 : 1000)
? Selectable valve characteristic: equal-percentage or linear
? High rangeability
? Operating voltage AC / DC 24 V
? Selectable standard signal inputs DC 0/2…10 V or DC 0/4…20 mA
? DC 0…20 V Phs phase-cut signal input for Staefa controllers
? Indication of operating state, visible from the outside
? Accurate position feedback signal by inductive stroke measurement
? Spring return facility: A ? AB closed when deenergized
? Low friction, robust and maintenance-free
? Including fittings

Siemens QFM21.. Duct sensor for rel. humidity / temperature

Device type QFM21..
Designation Duct sensors for humidity and
temperature
Product range SymaroTM

Modulating control valves with magnetic actuator,PN 16
MVF461H..
for hot water, high temperature hot water and steam
• Short positioning time (<2 s), high resolution (1 : 1000)
• Selectable valve characteristic: Equal-percentage or linear
• High rangeability
• Selectable standard interface DC 0/2…10 V or DC 0/4…20 mA
• Phase-cut signal input for Staefa controllers
• Position control and position feedback signal
• Wear-free inductive stroke measurement
• Spring return facility: A → AB closed when deenergized
• Low friction, robust and maintenance-free

Modulating refrigerant valves with magnetic actuator, PS45
MVL661..-..
Hermetically sealed, for safety refrigerants
· One valve type for expansion, hot-gas and suction throttle applications
· Hermetically sealed towards outside
· Selectable standard interface DC 0/2…10 V or DC 0/4…20 mA
· High resolution and control accuracy
· Precise positioning control and position feedback signal
· Short positioning time (< 1 s)
· Closed when deenergized
· Robust and maintenance-free
· Six valve sizes with kvs values from 0.25 to 12 m³/h
Use
The MVL661..-.. refrigerant valve is designed for modulating control of refrigerant
circuits including chillers and heat pumps. It can be used in expansion, hot-gas and
suction throttle applications as well as with all commonly used safety refrigerants (R22,
R134a, R227ea, R404A, R407C, R410A, etc.) and R744 (CO2).

 

SIEMENS
Modulating refrigerant valves with magnetic actuator‚ PS43
M3FB..LX..

Soldered connection‚ hermetically sealed

•Modulating control valve for hot-gas applications for capacity control of refrigeration units and heat recovery systems
•For organic safety refrigerants
•AC 24 V operating voltage or power signal DC 0…20 V Phs (phase cut)
•Selectable electrical interface ZM.. with DC 0…10 V, DC 4…20 mA or DC 0…20 V Phs positioning signal
•High resolution and control accuracy
•Short positioning time (< 1 s)
•Port AB  A closed when de-energized
•Robust and maintenance-free
•DN 15…32, kvs values 0.6…12 m3/h