BELIMO

BELIMO

Outdoor sensor with weather shield Humidity /
Temperature

Active sensor (4…20 mA) for measuring the
relative or absolute humidity and temperature
in outdoor areas. Instead of the humidity signal,
the enthalpy or the dewpoint can be selected as
an output signal. IP65 / NEMA 4X rated
enclosure.

Outdoor Humidity, Temperature Sensor with
weather shield

Active humidity and temperature sensor
(4…20 mA) for outside applications. The
radiation shield protects the outside sensors
from rain and radiated heat. With the curved
shape and color of the plates air flow is able
to move across the sensors to keep
radiated temperatures from rooftops and
surrounding surfaces from affecting
humidity readings.

Duct Sensor CO₂

For CO₂ measurement in duct applications.
Dual channel CO₂ technology.
NEMA 4X / IP65 rated enclosure.

Differential Pressure Sensor

Differential pressure transmitter with 8
selectable ranges and Modbus functionality.
NEMA 4X / IP65 rated enclosure. For
monitoring the differential pressure of air
and other non-flammable and nonaggressive
gases. Monitoring air filters,
fans, industrial cooling air cycles, control of
air and fire dampers.
Options available with LCD display.

Differential Pressure Sensor

Differential pressure transmitter with 8
selectable ranges and Modbus functionality.
NEMA 4X / IP65 rated enclosure. For
monitoring the differential pressure of air
and other non-flammable and nonaggressive
gases. Monitoring air filters,
fans, industrial cooling air cycles, control of
air and fire dampers.
Options available with LCD display.

Differential Pressure Sensor

Differential pressure transmitter with 8
selectable ranges and outputs 0…5 V,
0…10 V or 4…20 mA. NEMA 4X / IP65 rated
enclosure. For monitoring the differential
pressure of air and other non-flammable
and non-aggressive gases. Monitoring air
filters, fans, industrial cooling air cycles,
control of air and fire dampers.
Options available with LCD display,
Autozero feature.

Communicative damper actuator in IP66/67
protective housing for adjusting dampers in
HVAC plants, comparable industrial plants and
technical building installations
• Torque motor 160 Nm
• Nominal voltage AC 24…240 V / DC 24…125 V
• Control modulating, communicative, hybrid
• With 2 integrated auxiliary switches
• Conversion of sensor signals
• Communication via BACnet MS/TP, Modbus
RTU, Belimo-MP-Bus or conventional contro

Damper actuator in the IP66/67 protective
housing for adjusting dampers in HVAC
plants, comparable industrial plants and
technical building installations
• Torque motor 160 Nm
• Nominal voltage AC 24…240 V /
DC 24…125 V
• Control Open/close, 3-point
• with 2 integrated auxiliary switches

Rotary actuator fail-safe for adjusting
dampers in technical building installations
• Air damper size up to approx. 0.5 m²
• Torque motor 2.5 Nm
• Nominal voltage AC/DC 24 V
• Control Open/close

Communicative damper actuator fail-safe and
extended functionalities in the IP66/67
protective housing for adjusting dampers in
HVAC plants, comparable industrial plants
and technical building installations
• Torque motor 160 Nm
• Nominal voltage AC 24…240 V /
DC 24…125 V
• Control modulating, communicative, hybrid
• with 2 integrated auxiliary switches
• Conversion of sensor signals
• Communication via BACnet MS/TP, Modbus
RTU, Belimo-MP-Bus or conventional control

RobustLine damper actuator for adjusting
dampers in HVAC plants, comparable industrial
plants and technical building installations
• Air damper size up to approx. 2 m²
• Torque motor 10 Nm
• Nominal voltage AC 100…240 V
• Control Open/close, 3-point
• Optimum protection against corrosion and
chemical influences, UV radiation, damp and
condensation (for use in ambient temperatures
up to –40°C, there is a separate actuator
available with built-in heater)

RobustLine damper actuator for adjusting
dampers in HVAC plants, comparable
industrial plants and technical building
installations
• Air damper size up to approx. 2 m²
• Torque motor 10 Nm
• Nominal voltage AC 100…240 V
• Control Open/close, 3-point
• with integrated auxiliary switch
• Optimum protection against corrosion and
chemical influences, UV radiation, damp and
condensation

Modulating RobustLine damper actuator for
adjusting dampers in HVAC plants,
comparable industrial plants and technical
building installations
• Air damper size up to approx. 2 m²
• Torque motor 10 Nm
• Nominal voltage AC 100…240 V
• Control modulating 2…10 V
• Position feedback 2…10 V
• Optimum protection against corrosion and
chemical influences, UV radiation, damp and
condensation

RobustLine damper actuator for adjusting
dampers in HVAC plants, comparable industrial
plants and technical building installations
• Air damper size up to approx. 2 m²
• Torque motor 10 Nm
• Nominal voltage AC/DC 24 V
• Control Open/close, 3-point
• Optimum protection against corrosion and
chemical influences, UV radiation, damp and
condensation

RobustLine damper actuator for adjusting
dampers in HVAC plants, comparable
industrial plants and technical building
installations
• Air damper size up to approx. 2 m²
• Torque motor 10 Nm
• Nominal voltage AC/DC 24 V
• Control Open/close, 3-point
• with integrated auxiliary switch
• Optimum protection against corrosion and
chemical influences, UV radiation, damp and
condensation

Modulating RobustLine damper actuator for
adjusting dampers in HVAC plants, comparable
industrial plants and technical building
installations
• Air damper size up to approx. 2 m²
• Torque motor 10 Nm
• Nominal voltage AC/DC 24 V
• Control modulating 2…10 V
• Position feedback 2…10 V
• Optimum protection against corrosion and
chemical influences, UV radiation, damp and
condensation