Shop

You are here:

Spring return actuator with emergency function for adjusting air dampers in ventilation and air conditioning systems in buildings
• For air dampers up to approx. 4 m2
• Torque 20 Nm
• Nominal voltageeAC 230 V
• Control: Open-close

Spring return actuator with emergency function for adjusting air dampers in ventilation and air conditioning systems in buildings
• For air dampers up to approx. 2 m2
• Torque 10 Nm
• Nominal voltageeAC 230 V
• Control: Open-close
• Two integrated auxiliary switches

Spring return actuator with emergency function for adjusting air dampers in ventilation and air conditioning systems in buildings
• For air dampers up to approx. 2 m2
• Torque 10 Nm
• Nominal voltageeAC 230 V
• Control: Open-close

Modulating damper actuator for adjusting dampers in technical building installations
• Air damper size up to approx. 3.2 m²
• Nominal torque 16 Nm
• Nominal voltage AC/DC 24 V
• Control modulating DC (0)2…10 V
• Position feedback DC 2…10 V
• Running time motor 7 s

Damper actuator for adjusting dampers in technical building installations
• Air damper size up to approx. 3.2 m²
• Nominal torque 16 Nm
• Nominal voltage AC/DC 24 V
• Control Open-close (unsuitable for 3-point controls)
• Running time motor 7 s

Damper actuator for adjusting dampers in technical building installations
• Air damper size up to approx. 3.2 m²
• Nominal torque 16 Nm
• Nominal voltage AC 230 V
• Control Open-close, 3-point
• Running time motor 20 s

Damper actuator for adjusting dampers in technical building installations
• Air damper size up to approx. 3.2 m²
• Nominal torque 16 Nm
• Nominal voltage AC/DC 24 V
• Control Open-close, 3-point
• Running time motor 20 s

Modulating damper actuator for adjusting dampers in technical building installations
• Air damper size up to approx. 1.5 m²
• Nominal torque 8 Nm
• Nominal voltage AC/DC 24 V
• Control Modulating DC (0)2…10 V
• Position feedback DC 2…10 V
• Running time motor 4 s

Damper actuator for adjusting dampers in technical building installations
• Air damper size up to approx. 1.5 m²
• Nominal torque 8 Nm
• Nominal voltage AC/DC 24 V
• Control Open-close (unsuitable for 3-point controls)
• Running time motor 4 s

Modulating damper actuator for adjusting dampers in technical building installations
• Air damper size up to approx. 0.8 m²
• Nominal torque 4 Nm
• Nominal voltage AC/DC 24 V
• Control modulating DC (0)2…10 V
• Position feedback DC 2…10 V
• Running time motor 2.5 s

Damper actuator for adjusting dampers in technical building installations
• Air damper size up to approx. 0.8 m²
• Nominal torque 4 Nm
• Nominal voltage AC/DC 24 V
• Control Open-close (unsuitable for 3-point controls)
• Running time motor 2.5 s

Modulating rotary actuator for butterfly valves with ISO 5211-F07 mounting flange
• Air damper size up to approx. 8 m²
• Nominal torque 40 Nm
• Nominal voltage AC/DC 24 V
• Control modulating DC (0)2…10 V
• Position feedback DC 2…10 V
• Design life SuperCaps: 15 years
• Optimum weather protection for use outdoors (for use in ambient temperatures up to –40°C, there is a separate actuator available with built-in heater ex works)