Shop

You are here:

Damper actuator for adjusting dampers in technical building installations
• Air damper size up to approx. 1 m²
• Nominal torque 5 Nm
• Nominal voltage AC/DC 24 V
• Control Open-close, 3-point
• With integrated auxiliary switch

Modulating damper actuator for adjusting dampers in technical building installations
• Air damper size up to approx. 1 m²
• Nominal torque 5 Nm
• Nominal voltage AC/DC 24 V
• Control Modulating DC (0)2…10 V
• Position feedback DC 2…10 V

SERIES MS2 | DWYER

MAGNESENSE® II DIFFERENTIAL PRESSURE TRANSMITTER
Monitors Pressure, Air Velocity & Air Flow, BACnet/Modbus® Communications

FEATURES/BENEFITS
• Field selectable ranges and output signal reduce inventory and the chances of
ordering an incorrect part
• BACnet or Modbus serial communications reduce wiring cost by daisy-chaining
the transmitters
• Our integral field-upgradeable display or plug-in remote display tool save
upfront material cost and allow for local viewing of measurements
APPLICATIONS
• Filter monitoring in air handler units
• Building pressure in pharmaceutical-semi-conductor clean rooms
• Duct static pressure in commercial buildings
• Air velocity/flow in VAV systems

SERIES DM-1000 | DWYER

DIGIMAG® DIGITAL DIFFERENTIAL PRESSURE AND FLOW GAGES
24 Volt or Battery Powered, Fits in Magnehelic® Gage Cut-Out

FEATURES/BENEFITS
• Field programmed reduces installation time
• User selectable parameters for pressure, air velocity or flow permits same
device for multiple applications
• Specialized filter set point for alerts when maintenance is due
• Security levels permit matches the correct access to right skill
• Power versatility works with 9-24 VDC or 9 V battery allows deployment in a
variety of spaces wired or not
APPLICATIONS
• Filter monitoring
• Air velocity or flow
• Blower vacuum monitoring
• Fan pressure indication
• Duct, room or building pressures
• Clean room positive pressure indication

Damper actuator for adjusting dampers in technical building installations
• Air damper size up to approx. 0.4 m²
• Nominal torque 2 Nm
• Nominal voltage AC/DC 24 V
• Control Open-close, 3-point
• Running time motor 35 s

Damper actuator for adjusting dampers in technical building installations
• Air damper size up to approx. 0.4 m²
• Nominal torque 2 Nm
• Nominal voltage AC/DC 24 V
• Control Open-close, 3-point
• Running time motor 35 s
• With integrated auxiliary switch

Modulating damper actuator for adjusting dampers in technical building installations
• Air damper size up to approx. 0.4 m²
• Nominal torque 2 Nm
• Nominal voltage AC/DC 24 V
• Control Modulating DC (0)2…10 V
• Position feedback DC 2…10 V
• Running time motor 35 s

Damper actuator for adjusting dampers in technical building installations
• Air damper size up to approx. 0.4 m²
• Nominal torque 2 Nm
• Nominal voltage AC 230 V
• Control Open-close, 3-point
• Running time motor 35 s

Damper actuator for adjusting dampers in technical building installations
• Air damper size up to approx. 0.4 m²
• Nominal torque 2 Nm
• Nominal voltage AC 230 V
• Control Open-close, 3-point
• Running time motor 35 s
• With integrated auxiliary switch

Modulating damper actuator for adjusting dampers in technical building installations
• Air damper size up to approx. 0.4 m²
• Nominal torque 2 Nm
• Nominal voltage AC 230 V
• Control Modulating DC (0)2…10 V
• Position feedback DC 2…10 V
• Running time motor 35 s

Short facts about RCF-230CD
• Supply voltage 230 V AC
• Inputs for presence detector and/or window contact
• Built-in relays for a 3-speed fan, 230 V AC
• Input for automatic change-over cooling/heating
• BTL tested from software version 1.2-1-00

Universal controller with P or PI action for heating, ventilation and air conditioning. 

Auxiliary functions

  • PI limiter function (absolute and relative limit)
  • Remote setpoint
  • Setpoint compensation
  • Winter/summer mode changeover (analogue or digital input)
  • Cascade control
  • Maximum priority for cooling / dehumidifying