Shop
- Home
- Products
Modulating refrigerant valves with magnetic actuator, PS45
MVL661..-..
Hermetically sealed, for safety refrigerants
· One valve type for expansion, hot-gas and suction throttle applications
· Hermetically sealed towards outside
· Selectable standard interface DC 0/2…10 V or DC 0/4…20 mA
· High resolution and control accuracy
· Precise positioning control and position feedback signal
· Short positioning time (< 1 s)
· Closed when deenergized
· Robust and maintenance-free
· Six valve sizes with kvs values from 0.25 to 12 m³/h
Use
The MVL661..-.. refrigerant valve is designed for modulating control of refrigerant
circuits including chillers and heat pumps. It can be used in expansion, hot-gas and
suction throttle applications as well as with all commonly used safety refrigerants (R22,
R134a, R227ea, R404A, R407C, R410A, etc.) and R744 (CO2).
Modulating damper actuator for adjusting dampers in technical building installations
• Air damper size up to approx. 2 m²
• Nominal torque 10 Nm
• Nominal voltage AC/DC 24 V
• Control Modulating DC (0)2…10 V
• Position feedback DC 2…10 V
Damper actuator for adjusting dampers in technical building installations
• Air damper size up to approx. 2 m²
• Nominal torque 10 Nm
• Nominal voltage AC/DC 24 V
• Control Open-close, 3-point
• With integrated feedback potentiometer
Damper actuator for operating air control dampers in ventilation
and air-conditioning systems for building services installations
• For air control dampers up to
approx. 2 m2
• Torque 10 Nm
• Nominal voltage AC/DC 24 V
• Control: Open-close or 3-point
Damper actuator for adjusting dampers in technical building installations
• Air damper size up to approx. 1 m²
• Nominal torque 5 Nm
• Nominal voltage AC/DC 24 V
• Control Open-close, 3-point
• Running time motor 35 s
SIEMENS
Modulating refrigerant valves with magnetic actuator‚ PS43
M3FB..LX..
Soldered connection‚ hermetically sealed
•Modulating control valve for hot-gas applications for capacity control of refrigeration units and heat recovery systems
•For organic safety refrigerants
•AC 24 V operating voltage or power signal DC 0…20 V Phs (phase cut)
•Selectable electrical interface ZM.. with DC 0…10 V, DC 4…20 mA or DC 0…20 V Phs positioning signal
•High resolution and control accuracy
•Short positioning time (< 1 s)
•Port AB A closed when de-energized
•Robust and maintenance-free
•DN 15…32, kvs values 0.6…12 m3/h
Modulating damper actuator for adjusting dampers in technical building installations
• Air damper size up to approx. 1 m²
• Nominal torque 5 Nm
• Nominal voltage AC/DC 24 V
• Control Modulating DC (0)2…10 V
• Position feedback DC 2…10 V
• Running time motor 35 s
Damper actuator for adjusting dampers in technical building installations
• Air damper size up to approx. 1 m²
• Nominal torque 5 Nm
• Nominal voltage AC 230 V
• Control Open-close, 3-point
• Running time motor 35 s
Damper actuator for adjusting dampers in technical building installations
• Air damper size up to approx. 1 m²
• Nominal torque 5 Nm
• Nominal voltage AC 230 V
• Control Open-close, 3-point
Damper actuator for adjusting dampers in technical building installations
• Air damper size up to approx. 1 m²
• Nominal torque 5 Nm
• Nominal voltage AC 230 V
• Control Open-close, 3-point
• With integrated auxiliary switch
Modulating damper actuator for adjusting dampers in technical building installations
• Air damper size up to approx. 1 m²
• Nominal torque 5 Nm
• Nominal voltage AC 230 V
• Control Modulating DC (0)2…10 V
• Position feedback DC 2…10 V
Damper actuator for adjusting dampers in technical building installations
• Air damper size up to approx. 1 m²
• Nominal torque 5 Nm
• Nominal voltage AC/DC 24 V
• Control Open-close, 3-point