Shop
- Home
- Products
Characterised control valve with sensoroperated flow rate or power control with failsafe, power and energy-monitoring function, 2-
way, Flange, PN 16 (Energy Valve)
• Nominal voltage AC/DC 24 V
• Control modulating, communicative, hybrid,
Cloud
• For closed cold and warm water systems
• For modulating control of air-handling and
heating systems on the water side
• Ethernet 10/100 Mbit/s, TCP/IP, integrated
web server
• Communication via BACnet, Modbus, Belimo
MP-Bus or conventional control
• optional Belimo Cloud connection
• Glycol monitoring
Characterised control valve with thermal energy
meter, sensor-operated flow or power control,
power and energy monitoring function, 2-way,
internal and external thread, PN 25
• Nominal voltage AC/DC 24 V
• Control modulating, communicative, hybrid
• For closed cold and warm water systems
• For modulating control of air-handling and
heating systems on the water side
• Ethernet 10/100 Mbit/s, TCP/IP, integrated
web server
• Communication via BACnet, Modbus, Belimo
MP-Bus or conventional control
• PoE (Power over Ethernet) Power supply
possible
• Conversion of sensor signals
• Glycol monitoring
• Power control, flow control, posit
Characterised control valve with sensoroperated flow rate or power control, power and
energy-monitoring function, 2-way, Flange,
PN 16 (Energy Valve)
• Nominal voltage AC/DC 24 V
• Control modulating, communicative, hybrid,
Cloud
• For closed cold and warm water systems
• For modulating control of air-handling and
heating systems on the water side
• Ethernet 10/100 Mbit/s, TCP/IP, integrated
web server
• Communication via BACnet, Modbus, Belimo
MP-Bus or conventional control
• optional Belimo Cloud connection
• Glycol monitoring
Characterised control valve with thermal
energy meter, certified for heating
applications according to MID, fulfills the
requirements of EN 1434. Sensor-operated
flow rate or power control, power and energy
monitoring function, 2-way, internal thread,
PN 25
• Nominal voltage AC/DC 24 V
• Control modulating, communicative, hybrid
• For closed cold and warm water systems
• For modulating control of air-handling and
heating systems on the water side
• Ethernet 10/100 Mbit/s, TCP/IP, integrated
web server
• Communication via BACnet, Modbus, Belimo
MP-Bus or conventional control
• PoE (Power over Ethernet) Power supply
possible
• Conversion of sensor signals
Characterised control valve with thermal energy
meter, sensor-operated flow or power control,
power and energy monitoring function, 2-way,
internal and external thread, PN 25
• Nominal voltage AC/DC 24 V
• Control modulating, communicative, hybrid
• For closed cold and warm water systems
• For modulating control of air-handling and
heating systems on the water side
• Ethernet 10/100 Mbit/s, TCP/IP, integrated
web server
• Communication via BACnet, Modbus, Belimo
MP-Bus or conventional control
• PoE (Power over Ethernet) Power supply
possible
• Conversion of sensor signals
• Glycol monitoring
• Power control, flow control, position control
and differential pressure control
Fail-Safe actuator used in typical Fire and Smoke
damper applications
• Torque motor 30 in-lb [3.5 Nm]
• Nominal voltage AC 230 V
• Control On/Off
• @ 350°F [177°C] for 30 min
• 15 s, <15 s Motor/Fail-safe
• 2x SPST
Fail-Safe actuator used in typical Fire and Smoke
damper applications
• Torque motor 30 in-lb [3.5 Nm]
• Nominal voltage AC 120 V
• Control On/Off
• @ 350°F [177°C] for 30 min
• 15 s, <15 s Motor/Fail-safe
• 2x SPST
Fail-Safe actuator used in typical Fire and Smoke
damper applications
• Torque motor 180 in-lb [20 Nm]
• Nominal voltage AC/DC 24 V
• Control Modulating
• @ 250°F [121°C] for 30 min
• 75 s, <20 s Motor/Fail-safe
Fail-Safe actuator used in typical Fire and Smoke
damper applications
• Torque motor 180 in-lb [20 Nm]
• Nominal voltage AC/DC 24 V
• Control On/Off
• @ 350°F [177°C] for 30 min
• 25 s, <15 s Motor/Fail-safe
• 2x SPST