22PE-1U.., BELIMO, Thermal energy meter, AC/DC 24 V

Thermal energy meter

Thermal energy meter for measuring energy in
a closed heating or cooling circuit. It is
equipped with automatic glycol compensation
and automatically and continuously measures
the glycol content in the medium and
compensates it, thus ensuring reliable
measurement of the thermal energy. If
required, the power supply can be provided via
PoE (Power over Ethernet). Communication is
provided via BACnet, Modbus, MP-Bus or M-Bus
(with Converter). Parametrisation is done with
the Belimo Assistant App via NFC technology or
via web server. The commissioning report can
be generated automatically. Connection to the
Belimo Cloud is possible.

22PEM-1U.., BELIMO, Thermal energy meter MID / EN 1434, AC/DC 24 V

Thermal energy meter

Thermal energy meter for measuring energy
in a heating or cooling circuit. The device is
certified for heating applications according to
MID and fulfills the requirements of EN1434.
If required, the power supply can be provided
via PoE (Power over Ethernet).
Communication is provided via BACnet,
Modbus or MP-Bus. Configuration is done
with the Belimo Assistant App via NFC
technology or via web server. The
commissioning report can be generated
automatically. Connection to the Belimo
Cloud is possible.

22PF-1U.., BELIMO, Flow sensor, AC/DC 24 V

Flow sensor

Ultrasonic flow sensor for closed cold and hot
water systems containing water or waterglycol
mixtures. It continuously measures the glycol
content of the medium and compensates for it
to ensure an accurate measurement.
The flow sensor is installed in the system via
two external threads (ISO 228-1). The power
supply is AC/DC 24 V and the output signal is
0…10 V or communicative via BACnet MSTP,
Modbus RTU or MP-Bus.
The flow rate can be accumulated.
Programming is carried out with the Belimo
Assistant App via NFC technology.

C3..Q-.., Changeover zone valve, 3-way, Internal thread

Changeover zone valve, 3-way, Internal thread
• For closed cold and warm water systems
• For switching functions and 2-point controls
on the water side of air-handling units and
heating systems
• Snap-assembly of the actuator

C2..Q-.., Zone valve, 2-way, Internal thread

Zone valve, 2-way, Internal thread
• For closed cold and warm water systems
• For shut-off functions and modulating controls
on the water side of air-handling units and
heating systems.
• Snap-assembly of the actuator
• kvs variable

EP..R2+KBAC, Characterised control valve with sensoroperated flow control with fail-safe, 2-way, Internal and external thread, PN 25 (EPIV)

Characterised control valve with sensoroperated flow control with fail-safe, 2-way,
Internal and external thread, PN 25 (EPIV)
• Nominal voltage AC/DC 24 V
• Control modulating, communicative, hybrid
• For closed cold and warm water systems
• For modulating control of air-handling and
heating systems on the water side
• Communication via Belimo MP-Bus or
conventional control
• Conversion of active sensor signals and
switching contacts
• Measurement of the fluid temperature

EP..R2+BAC,Characterised control valve with sensoroperated flow control, 2-way, Internal and external thread, PN 25 (EPIV)

Characterised control valve with sensoroperated flow control, 2-way, Internal and
external thread, PN 25 (EPIV)
• Nominal voltage AC/DC 24 V
• Control modulating, communicative, hybrid
• For closed cold and warm water systems
• For modulating control of air-handling and
heating systems on the water side
• Communication via BACnet MS/TP, Modbus
RTU, Belimo-MP-Bus or conventional control
• Conversion of active sensor signals and
switching contacts
• Measurement of the fluid temperature

EV..R2+BAC, ENERGY VALVE, Characterised control valve with thermal energy meter, sensor-operated flow or power control, power and energy monitoring function, 2-way, internal and external thread, PN 25

Characterised control valve with thermal energy
meter, sensor-operated flow or power control,
power and energy monitoring function, 2-way,
internal and external thread, PN 25

• Nominal voltage AC/DC 24 V
• Control modulating, communicative, hybrid
• For closed cold and warm water systems
• For modulating control of air-handling and
heating systems on the water side
• Ethernet 10/100 Mbit/s, TCP/IP, integrated
web server
• Communication via BACnet, Modbus, Belimo
MP-Bus or conventional control
• PoE (Power over Ethernet) Power supply
possible
• Conversion of sensor signals
• Glycol monitoring
• Power control, flow control, posit

EV..R2+MID, ENERGY VALVE, Characterised control valve with thermal energy meter, certified for heating applications according to MID, power and energy monitoring function, 2-way, internal thread, PN 25

Characterised control valve with thermal
energy meter, certified for heating
applications according to MID, fulfills the
requirements of EN 1434. Sensor-operated
flow rate or power control, power and energy
monitoring function, 2-way, internal thread,
PN 25
• Nominal voltage AC/DC 24 V
• Control modulating, communicative, hybrid
• For closed cold and warm water systems
• For modulating control of air-handling and
heating systems on the water side
• Ethernet 10/100 Mbit/s, TCP/IP, integrated
web server
• Communication via BACnet, Modbus, Belimo
MP-Bus or conventional control
• PoE (Power over Ethernet) Power supply
possible
• Conversion of sensor signals

EV..R2+BAC, ENERGY VALVE, Characterised control valve with thermal energy meter, sensor-operated flow, power control, energy monitoring function, 2-way, internal and external thread, PN 25

Characterised control valve with thermal energy
meter, sensor-operated flow or power control,
power and energy monitoring function, 2-way,
internal and external thread, PN 25
• Nominal voltage AC/DC 24 V
• Control modulating, communicative, hybrid
• For closed cold and warm water systems
• For modulating control of air-handling and
heating systems on the water side
• Ethernet 10/100 Mbit/s, TCP/IP, integrated
web server
• Communication via BACnet, Modbus, Belimo
MP-Bus or conventional control
• PoE (Power over Ethernet) Power supply
possible
• Conversion of sensor signals
• Glycol monitoring
• Power control, flow control, position control
and differential pressure control

SIEMENS,Modulating control valves with magnetic actuator,PN 16 MVF461H..

Modulating control valves with magnetic actuator,PN 16
MVF461H..
for hot water, high temperature hot water and steam
• Short positioning time (<2 s), high resolution (1 : 1000)
• Selectable valve characteristic: Equal-percentage or linear
• High rangeability
• Selectable standard interface DC 0/2…10 V or DC 0/4…20 mA
• Phase-cut signal input for Staefa controllers
• Position control and position feedback signal
• Wear-free inductive stroke measurement
• Spring return facility: A → AB closed when deenergized
• Low friction, robust and maintenance-free

SIEMENS, Modulating refrigerant valves with magnetic actuator‚ PS43, M3FB..LX..

SIEMENS
Modulating refrigerant valves with magnetic actuator‚ PS43
M3FB..LX..

Soldered connection‚ hermetically sealed

•Modulating control valve for hot-gas applications for capacity control of refrigeration units and heat recovery systems
•For organic safety refrigerants
•AC 24 V operating voltage or power signal DC 0…20 V Phs (phase cut)
•Selectable electrical interface ZM.. with DC 0…10 V, DC 4…20 mA or DC 0…20 V Phs positioning signal
•High resolution and control accuracy
•Short positioning time (< 1 s)
•Port AB  A closed when de-energized
•Robust and maintenance-free
•DN 15…32, kvs values 0.6…12 m3/h